Human Resources / Contact Us    
 
 
  Boxed Type PLC Splitter
Model:PLC-B
Planar Light wave Circuits (PLC) splitters are manufactured using silica glass waveguide circuits and extremely precise alignment of optic fibers in very small package. They split or combine light from one or two incoming fibers to multiple numbers of outgoing fibers. They perform uniformly over a wide spectral range, with ultra-low losses. splitters are highly compact, reliable and available in very wide range of fiber and connector types. All PLC splitters are fully compliant with the Telcordia GR-1209 & GR-1221 standard. Splitters contain no electronics and use no power. They are the network elements that put the passive in Passive Optical Network and are available in a variety of split ratios, including 1:2, 1:4, 1:8, 1:16, 1:32,1:64,2:8, 2:16, 2:32 & 2:64.
 
 
   
  • 1x4
    1x4
  • 1x32
    1x32
  • 2x8
    2x8
  • 2x16
    2x16
  • 2x32
    2x32
  • packaging
    packaging
  • packaging
    packaging
 

Standard Compliance
▪  Telcordia GR-1221-CORE-1999 & GR-1209-CORE-2001
▪  TIA/EIA-568B.3 Fiber Optic Cabling Components Standard
▪  IEE802.3z Standards for Fiber Optic Cabling
▪  RoHS Certified for European Market Requirements

Features & Benefits
▪  Low insertion losses, High Uniformity, High Reliability, High directivity
▪  Ultra-broadband performance (1250-1650nm)
▪  Low Polarization Dependant Loses (PDL) and Polarization Mode Dispersion (PMD)
▪  1 or 2 input channels and up to 64 output channels
▪  Ultra small, easy installation, suitable for all applications
▪  Available with all type of packages and connectors
▪  Ready for use in uncontrolled environment

Specifications
Telcordia 1209 & 1221 Test results:

Name of the test Condition Duration 
Temperature- Humidity aging 85°C and 85% RH 7 days 
Vibration 10 - 55Hz, 1.52mm double amplitude, in three axes 1 hour 
Component Impact Test Impact of 500g (mass<=0.125kg), 1ms , half sine pulse 2 impacts 
Temperature Cycling Test -40&deg;C to + 70&deg;C , Ramp rate: 1&deg;C /min, Dwell time >15min 10 cycles 
Temperature- Humidity cycling -40&deg;C to + 85&deg;C , between 10&deg;C and 23&deg;C - 85% RH, at 85&deg;C -20%RH, 
between 23&deg;C and 85&deg;C - maintain a linear change in RH, below 10&deg;C - uncontrolled RH 
14 days 
Water Immersion 43 &plusmn; 2&deg;C , PH 5.5 &plusmn; 0.5 7 days 
Fiber Side Pull test 0.23 kg load, 90&deg; angle , 2 directions 5 seconds 
Fiber Side Pull test 0.45 Kg load for Single Input Fiber , 1.5 Kg load for 8 Fiber Ribbon Outputs 5 seconds 

 
 

1 x N
ParameterUnit1 x 2 1 x 4 1 x 8 1 x 16 1 x 32 1 x 64 
Insertion Loss Max. dB3.8 7.0 10.4 13.9 17.2 22.0 
Channel Uniformity Max. dB0.6 0.5 0.5 1.4 1.6 2.5 
Polarization Dependent Loss Max. dB0.2 0.3 0.3 0.3 0.3 0.3 
Wavelength Dependent Loss Max. dB0.3 0.3 0.3 0.3 0.3 0.3 
Temperature Dependent Loss Max. dB0.5 0.5 0.5 0.5 0.5 0.5 
Connector Dependent Loss Max. dB0.2 0.2 0.2 0.2 0.2 0.2 
Operating Wavelength Min.-Maxnm1250 ~ 1650 
Return Loss Min. dB55 
Directivity Min. dB55 
Operating Temperature &deg;C -40 ~ + 85 
Storage Temperature &deg;C -40 ~ + 85 
Maximum Input Power Max. mW 500 
Fiber Type ITU G.652D or G.657A 

 

2 x N
Parameter Unit 2 x 2 2 x 4 2 x 8 2 x 16 2 x 32 2 x 64 
Insertion Loss Max. dB4.0 7.3 10.7 14 17.5 22.5 
Channel Uniformity Max. dB0.8 1.0 1.0 1.5 1.8 3.0 
Polarization Dependent Loss Max. dB0.2 0.3 0.3 0.3 0.3 0.4 
Wavelength Dependent Loss Max. dB0.3 0.3 0.3 0.3 0.3 0.3 
Temperature Dependent Loss Max. dB0.5 0.5 0.5 0.5 0.5 0.5 
Connector Dependent Loss Max. dB0.2 0.2 0.2 0.2 0.2 0.2 
Operating Wavelength Min.-Max. nm1250 ~ 1650 
Return Loss Min. dB55 
Directivity Min. dB55 
Operating Temperature &deg;C -40 ~ + 85 
Storage Temperature &deg;C -40 ~ + 85 
Maximum Input Power Max. mW500 
Fiber Type ITU G.652D or G.657A 

Ordering Information

Using the available configurations amend/create product codes using the formula below.

Part Number PLC-ABC-DEF-GHI

 

Ordering Guide

A

Input Port

1=1 Port, 2=2   Ports

B

Output Port

02=2 Ports, 16=16   Ports, 64=64   Ports

C

Packaging Type

B=Boxed   Type, M=Micro Type

D

Diameter of   Input Fiber

09=0.9mm, 20=2.0mm,   30=3.0mm

E

Input Fiber   Connector type

FP, SP, SA, LP (As noted in Connector type code chart )

F

Input Fiber   Length

10=1M, 15=1.5M,   20=2M

G

Diameter of   Output Fiber

09=0.9mm, 20=2.0mm,   30=3.0mm

H

Output Fiber   Connector type

FP, SP, SA, LP (As noted in Connector type   code chart )

I

Output Fiber   Length

05=0.5M, 10=1M,   15=1.5M,   20=2M

 

Connector Type Code

Code

Connector

Code

Connector

Code

Connector

Code

Connector

Code

Connector

Code

Connector

FP

FC/PC

FA

FC/APC

LP

LC/PC

LA

LC/APC

MU

MU

DN

DIN

SP

SC/PC

SA

SC/APC

TP

ST/PC

TA

ST/APC

MT

MTRJ

E2

E2000

 

Ordering Sample

Part Number

Description

PLC-108B-30SP05-30SP05

1*8 PLC   splitter, boxed type package, input and output fiber Ф 3, length 0.5M, and connector   SC/PC.

PLC-232M-09SP10-09SP10

2*32 PLC   splitter, micro type package, input   and output fiber Ф 0.9, length 1M, and connector SC/PC.


        Services & Support
  Fibre Optic Cable
Patch Cords and Cable Accessories
Termination and splicing
Fiber Optic Patch Panel
Copper Structured Cabling and Accessories
Company Profile
Corporate Culture
Factory equipment
Qualification
team of us
Company news
Industry news
Exhibition information
Human Resources
Feedback
Contact us
Design By lxhd.cnCopyright 2014 Alights Reserved. HNK Optic Equipment Co.,Limitedis